Filter Results By:

Products

Applications

Manufacturers

Showing results: 2596 - 2610 of 2684 items found.

  • PXIe-6378, 16 AI (16-Bit, 3.5 MS/s/ch), 4 AO, 48 DIO, PXI Multifunction I/O Module

    781476-01 - NI

    PXIe, 16 AI (16-Bit, 3.5 MS/s/ch), 4 AO, 48 DIO, PXI Multifunction I/O Module—The PXIe‑6378 is a simultaneous sampling, multifunction DAQ device. It offers analog I/O, digital I/O, four 32‑bit counters, and analog and digital triggering. Onboard NI‑STC3 timing and synchronization technology delivers advanced timing functionality, including independent analog and digital timing engines and retriggerable measurement tasks. The PXIe‑6378 is ideal for a variety of applications, such as IF digitization; transient recording; ISDN, ADSL, and POTS manufacturing test in the telecom industry; ultrasound and sonar testing; and high-energy physics. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.

  • Amplifier, Switch and Test Box

    CLIOQC Model V - Audiomatica

    The QCBOX Model 5 is a non-conventional unit designed to fulfil actual and future needs of an electro-acoustical analyzer like the CLIO system. It is USB linked to a PC and can be configured, with dedicated software controls, to assist frequency response and impedance measurements or to perform DC measurements. Using it for frequency response measurements acts as 50W power amplifier to drive the speaker or network under test while routing one-of-four inputs to the analyzer as well the current sensing output. The four inputs are able to provide a phantom power supply both for Audiomatica or general purpose microphones (0-24 V range, software controlled). Impedance measurements can be done either switching the D.U.T.’s load across the analyzer’s input or using a dedicated output, ISENSE, thus allowing impedance measurements in constant voltage mode as well voice coil current distortion analysis. An internal ADC measures the DC current into the voice coil. Thanks to an internal software controlled voltage generator the speaker can be driven with a superimposed DC voltage (±20V), allowing for measurements of large signal parameters. Two ADC converters with a ±2.5 V and ±5 V are available at inputs 3 and 4 to measure the displacement with a laser sensor or any other DC signal. A dedicated digital input handles an external foot pedal switch (or TTL signal) to be connected and triggers QC operations. A 6 bit output – 5 bit input TTL digital port is available to interface the QCBOX and driving software with external hardware (like turntables for example).The QCBOX Model 5 finds use both in laboratory for R&D applications and in production lines setups.

  • PXI Signal Insertion Switch Module

    NI

    PXI Signal Insertion Switch Modules, also known as fault insertion units (FIUs), provide a set of feedthrough channels, which make the switch transparent to the system when closed. You can open or short these channels to one of two fault buses, allowing you to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXI Signal Insertion Switch Module can validate the integrity of control systems including engine control units (ECUs) and full authority digital engine controls (FADECs). You can also use the FIU models for hardware-in-the-loop (HIL) applications and electronic reliability tests.

  • ADAQ Data Systems

    Atec, Inc.

    Atec’s Data Acquisition and Control System (ADAQ™) is a modern, full-featured, highly integrated hardware and software solution that is applicable for use with most commercial and military turbine engine test cell applications. Built upon National Instruments’ respected LabVIEW platform, ADAQ™ is robust, versatile, user friendly, and specifically designed to handle the demanding requirements of engine testing. It links seamlessly to digital engine modules (FADECs, DEECs, EECs, ECUs) as well as legacy analog and mechanical controls. Users can create, remove, calibrate and display channels, as well as generate custom calculations, screens and reports. Beyond the most impressive manual throttle control and operation available, Atec’s ADAQ™ additionally offers the option of fully automated testing.

  • Low Gauge Vacuum Tester

    G4103 - Gunson

    Suitable for use on all petrol engines and easily fits to most vehicles. Accurately measures pressures within the range minus 1 bar (30mHg) to plus 0.7 bar (10psi). Applications include: Engine Fault Finding, by using the gauge as an inlet manifold vacuum tester the following faults can be diagnosed: spark misfires, poor engine compression, mixture tool weak or too rich, ignition too advanced or too retarded, inlet manifold and carburettor air leaks, incorrect valve timing. Turbo boost gauge; testing boost pressure up to 0.7bar (10psi) and Petrol Pump Tester; tests electrical and mechanical petrol pumps (excluding high pressure pumps used on fuel injection engines)

  • High Power Programmable DC Power Supply

    IT6000D Series - I-TECH Electronic Co., Ltd

    IT6000D, single channel output programmable DC power supply, is applicable in laboratories and automatic test system to provide high-power and stable DC supply. The feature of autoranging output enables a wide range of voltage and current combinations at full power, unprecedentedly flexible. IT6000D Series has wide range of applications and its single unit provides power range of 6kW to 144kW, current up to 2040A, as well as its voltage up to 2250V. Besides, IT6000D provides multi built-in communication interfaces to simplify and accelerate the testing development. The compact 3U design saves rack space. Multi units of the same model can be paralleled easily to have higher power and the maximum power can reach up to 1.152 MW.

  • DC Power Supply

    PDS Series - Matrix Technology Inc.

    This series of products is programmable DC switching power supply with high accuracy and single output. It is light and compact, adjustable in voltage and current, and has multiple operating modes. The whole system is completely controlled by the microporcessor (mou), and can easily use the communication interface (re-232) to connect with the computer (PC) to meet the user's requirements for automatic testing and automatic control. The software instructions are completely in accordance with the scpi command. The format makes it easy for users to develop automatic test and automatic control applications. Due to the full digitalization of the system, the data input is completely controlled by the keyboard and knob, which is fast, accurate, and convenient. Can be widely used in electronic product development, device testing, communications industry, laboratories and scientific research institutions.

  • Broadband Amplifier - 4kHz to 6GHz with High Power Density

    BBA150 - Rohde & Schwarz GmbH & Co. KG

    The R&S®BBA150 broadband amplifiers cover a total of five frequency bands: 9 kHz to 250 MHz, 4 kHz to 400 MHz, 80 MHz to 1 GHz, 0.69 GHz to 3.2 GHz and 2.5 GHz to 6 GHz. They can be used to address a variety of applications, including the various standards for EMS measurements up to 6 GHz. In the industry environment, the R&S®BBA150 broadband amplifiers are suitable for development and product validation tests in quality assurance and in the development and production of components. Other fields of use include research, physical engineering and communications. The compact and modular design allows single band or multi band configurations in 4HU desktops or in 19" racks for high power.

  • PXI-5671, 2.7 GHz RF Vector Signal Generators

    779079-04 - NI

    2.7 GHz, Digital Upconverter Included, PXI Vector Signal Generator—The PXI‑5671 features quadrature digital upconversion, which reduces waveform download and signal generation time. It is a general-purpose vector signal generator that can generate standard modulation formats such as AM, FM, PM, ASK, FSK, MSK, GMSK, PSK, QPSK, PAM, and QAM. The PXIe‑5671 delivers a highly flexible and powerful solution for scientific research, consumer electronics, communications, aerospace/defense, and semiconductor test applications as well as emerging areas including software-defined radio, radio frequency identification (RFID), and wireless sensor networks. For specific communications standards, you can use various software add-ons to generate modulated signals according to standards such as WCDMA, DVB‑H, and ZigBee

  • PXIe-1095, 18-Slot (5 Hybrid Slots, 11 PXI Express Slots, 1 PXI Express System Timing Slot), Up to 24 GB/s PXI Chassis

    785971-01 - NI

    PXIe, 18-Slot (5 Hybrid Slots, 11 PXI Express Slots, 1 PXI Express System Timing Slot), Up to 24 GB/s PXI Chassis - The PXIe-1095 features a high-bandwidth backplane and up to 82 W of power and cooling in every slot to meet a wide range of high-performance test and measurement application needs. The chassis incorporates two hot-swappable power supplies to improve the mean time to repair (MTTR) of the PXI system; it also offers a Timing and Synchronization option that includes a built-in oven-controlled crystal oscillator (OCXO) for increased clock accuracy and external clock and trigger routing. It accepts PXI Express modules in every slot and supports standard PXI hybrid-compatible modules in up to five slots.

  • PCIe 4.0 Protocol Analyzer

    Summit T48 - Teledyne LeCroy

    Teledyne LeCroy’s Summit™ T48 joins the Summit™ T416 as the second protocol analyzer to be released in its family of tools supporting the PCIe 4.0 architecture. The new Summit™ T48 protocol analyzer based on the PCIe 4.0 specification supports up to 16GT/s and up to x8 lane width for protocol analysis. Companies that are interested in testing PCIe 4.0 based I/O cards such as Storage Controllers, Ethernet, Fibre Channel, Infiniband, and others will now be able to get all of the protocol analyzer debugging features they need, while being able to better manage their costs. SSD storage applications will also benefit from the integrated support for SSD bus protocols such as PCIe/ NVMe/ SMBus/ NVMe-MI/ TCG and others. When combined with Teledyne LeCroy’s Summit™ Z416 protocol exerciser, the Summit™ T48 will provide a deeper understanding of test results on a variety of test configurations. Teledyne LeCroy’s wide range of high speed interposers and probes provide full flexibility and connectivity to CEM and other form factor sockets on system boards as well as solder down and mid-bus probes.

  • High Performance Programmable AC Power Supply

    IT7600 Series - I-TECH Electronic Co., Ltd

    IT7600series high performance programmable AC power supplies, adopt advanced digital signal processing technology, with frequency up to 10-5000 Hz, built-inall-round power meter and large-screen oscilloscope function. Power up to 54kVA and support master-slave parallel, which can provide high-capacitysingle-phase or three-phase AC output. Some single-phase or three-phase products can be easily upgraded toAC600V (three-phase star connection downline voltage up to 1000V) output. IT7600 has built-in arbitrary waveform generator to simulate the harmonic and avariety of arbitrary waveforms output; also has strong exchange measurement and analysis functions. IT7600 can be widely used in many areas, such as newenergy, home appliances, power electronics, avionics, military, the development and application of IEC standard test and so on.

  • Handheld LCR Meter (100Hz to 100kHz)

    ST2822 - Saluki Technology Inc.

    ST2822 series handheld LCR meter is a portable handheld measuring instrument used to measure the parameters of inductance, capacitance, resistance and other components. Small in size, powered by 8.4V rechargeable battery (ST2822A is 9V non-rechargeable battery) or external power adapter, it can be used not only in desktop applications, but also in mobile measurement and handheld measurement.ST2822 series apply the ultra-low power consumption design and high density SMD assembly techniques and can simultaneously display primary and secondary parameters on a LCD display with backlight. The dual-color shell is gorgeously once shaped; and functions are easy to operate. The test frequency is up to 100 kHz, the readings of primary parameter 40,000 counts and the resolution of dissipation factor 0.0001. Accurate and convenient measurements of passive-components can be achieved in different occasions for a long time.

  • 6 Sided Bed of Nails Testers

    BoxProber Family - Test Electronics

    6 sided Bed of Nails circuit board test fixture. Probes top bottom and all 4 sides. Central camming mechanism pull plates inward. Mechanically or electrically actuated options. Designed primarily for testing products in plastics. Side access electrically probes outside panel connectors. The unit will also optically read LEDs and key segments off LCD displays. Solenoids will press buttons and servos will turn selector switches. DC motors are used to adjust multiple turn potentiometers. Microphone will detect audio output tones. Top and bottom of circuit boards can also be probed if removable access panels are available. This unit will also probe all 6 sides of a circuit board. This is typically utilized in applications where connector testing is required.

  • Millimeter Wave Continuously Variable Waveguide Attenuators

    Fairview Microwave Inc.

    Our millimeter wave variable waveguide attenuators allow designers and engineers to test their systems at various signal strengths and attenuation values to determine the optimum signal performance of the system. The key feature of these waveguide attenuators is that the attenuation level is adjusted using a built-in micrometer which enables repeatable and rapid re-setting to different attenuation levels without the need for additional external components. Our waveguide attenuators handle varying attenuation levels from 0 to 30 dB over the specified band allowing the designer to tune the attenuation level needed for the application. These continuously variable waveguide attenuators cover a broad frequency range of 33 to 110 GHz in five bands and also display flat performance across a wide band with low insertion loss.

Get Help